Gas \u00b7 UK

Gas Installation Symbols — UK (BS 1553 / Gas Safe)

These symbols appear on gas installation pipe diagrams, CP12 gas safety records, and commissioning documents in the UK. They follow BS 1553-1 and Gas Safe Register technical standards. Every Gas Safe registered engineer should be familiar with these when producing or reading installation drawings.

BS 1553-1:1977 / Gas Safe Technical Bulletins15 symbols

Pipework

Low Pressure Gas Pipe

Low pressure gas supply pipe (below 75 mbar)

BS 1553-1

Medium Pressure Gas Pipe

Medium pressure gas pipe (75 mbar to 2 bar)

BS 1553-1

Concealed Gas Pipe

Gas pipe run concealed within the building structure

BS 1553-1

Tee Piece

Gas pipe tee junction

BS 1553-1

Test Point

Gas pressure test point nipple

BS 6891 / Gas Safe

Meters & Controls

Gas Meter

Gas supply meter position

BS 1553-1

Emergency Control Valve

Emergency gas shut-off valve (ECV) at meter

BS 1553-1 / Gas Safe

Isolating Valve

Manual gas isolation valve for individual appliance

BS 1553-1

Pressure Regulator

Gas pressure regulator / governor

BS 1553-1

Appliances

Gas Boiler

Wall-hung or floor-standing gas boiler

BS 1553-1 / Gas Safe

Gas Fire / Heater

Gas-fired room heater or decorative fire

BS 1553-1

Gas Hob / Cooktop

Gas cooking hob / cooktop

BS 1553-1

Gas Oven

Gas-fired oven / range cooker

BS 1553-1

Ventilation & Flues

Flue Terminal

Flue / chimney terminal point (balanced or open flue)

BS 5440 / Gas Safe

Air Vent

Fixed ventilation opening for combustion air supply

BS 5440-2 / Gas Safe

Download this chart

Get a free branded PNG image of all 15 symbols. Print it, pin it to your workshop wall, or save it to your phone.

Frequently asked questions about gas symbols

Where are gas installation symbols officially defined?
BS 1553-1:1977 (Specification for graphical symbols for general engineering) covers piping and gas symbols. Gas Safe Register technical bulletins provide additional guidance on diagram conventions.
Do I need to draw pipe diagrams for a CP12?
A CP12 gas safety record requires a schematic showing the installation pipework layout, appliance positions, and safety controls. You don’t need architect-quality drawings, but the symbols should be recognisable.
What is the difference between LP and MP pipe symbols?
Low Pressure (LP) is below 75 mbar — this is standard domestic supply pressure. Medium Pressure (MP) is 75 mbar to 2 bar, used for longer supply runs or commercial installations.