Fire Alarm System Record of Completion

This is the NFPA 72 Record of Completion — the standard document confirming a new or modified fire alarm system has been installed and acceptance-tested. It captures control unit and monitoring details, the full device inventory, and the acceptance test checklist.

NFPA 72 (National Fire Alarm and Signaling Code)Valid: One-off (no expiry)

No credit card required. Set up in 30 seconds.

Sample FA Record of Completion certificate

Sample Fire Alarm System Record of Completion certificate created with CertBox, showing the professional PDF layout with control unit technology, zones/loops and means of transmission to monitoring, device inventory by type, manufacturer and model, acceptance test checklist — initiating, notification, power, monitoring, ancillary functions

Sample FA Record of Completion with fictional data. All personal details shown are fake.

What it covers

  • Control unit technology, zones/loops and means of transmission to monitoring
  • Device inventory by type, manufacturer and model
  • Acceptance test checklist — initiating, notification, power, monitoring, ancillary functions
  • Secondary power sizing and calculated standby/alarm duration
  • System acceptance decision and outstanding deficiencies

Who needs a FA Record of Completion?

Fire alarm installing contractors
AHJs accepting new or modified systems
Building owners
Central station monitoring companies

Create your FA Record of Completion with CertBox

1

Fill in the form

Pick FA Record of Completion from the list, fill in the fields on your phone.

2

Compliance checks run

Built-in validation catches missing fields and out-of-range readings.

3

PDF generated instantly

Professional PDF ready to share via secure link or download.

Frequently asked questions about FA Record of Completion

What is a Record of Completion?
It is the document NFPA 72 requires be prepared for every new or modified fire alarm system, recording the system design, devices installed, and confirmation that the required acceptance tests were performed before the system is placed in service.
How much standby power must a fire alarm system have?
NFPA 72 sets a minimum of 24 hours of standby power followed by 5 minutes of alarm operation for most systems (15 minutes for voice/mass notification systems), unless the approved design specifies otherwise.