Electricians Create in CertBox

Lighting Controls Acceptance Test Certificate

This certificate documents the functional acceptance testing of automatic lighting controls in a commercial building — occupancy/vacancy sensors, daylighting controls, demand-responsive controls and outdoor photocontrols — required before occupancy under California Title 24 or an equivalent commercial energy code (IECC C405 / ASHRAE 90.1) adopted by other states.

California Title 24, Part 6 (acceptance testing via a CEC-approved ATTCP, e.g. CALCTP); IECC C405 and ASHRAE 90.1 mandatory lighting-control functional testing in other adopting statesValid: One-off (no expiry)

No credit card required. Set up in 30 seconds.

Sample Lighting Controls Acceptance certificate

Sample Lighting Controls Acceptance Test Certificate certificate created with CertBox, showing the professional PDF layout with occupancy/vacancy sensor zones and automatic shut-off, daylighting sensor calibration and dimming response, demand-responsive control signal reception

Sample Lighting Controls Acceptance with fictional data. All personal details shown are fake.

What it covers

  • Occupancy/vacancy sensor zones and automatic shut-off
  • Daylighting sensor calibration and dimming response
  • Demand-responsive control signal reception
  • Outdoor photocontrol/astronomical time switch
  • Manual override verification
  • Applicable energy code and overall result

Who needs a Lighting Controls Acceptance?

Acceptance test technicians
Electrical contractors
Commercial building owners
Energy code officials

Create your Lighting Controls Acceptance with CertBox

1

Fill in the form

Pick Lighting Controls Acceptance from the list, fill in the fields on your phone.

2

Compliance checks run

Built-in validation catches missing fields and out-of-range readings.

3

PDF generated instantly

Professional PDF ready to share via secure link or download.

Frequently asked questions about Lighting Controls Acceptance

Who can perform Title 24 lighting controls acceptance testing?
In California, Title 24 Part 6 requires acceptance testing to be performed by an Acceptance Test Technician (ATT) certified through a CEC-approved Acceptance Test Technician Certification Provider (ATTCP), such as CALCTP, and employed by a registered Acceptance Test Employer (ATE). Other states that adopt mandatory lighting-control functional testing via the IECC (C405) or ASHRAE 90.1 typically require a qualified person experienced with the systems, without California's specific ATT/ATTCP credential — confirm what your AHJ requires.
What is tested during lighting controls acceptance testing?
Testing verifies that occupancy/vacancy sensors switch correctly and provide automatic shut-off, daylighting sensors are calibrated and dim or switch fixtures in response to daylight, demand-responsive controls receive the utility signal, and outdoor lighting is controlled by a photocontrol or astronomical time switch. Results and any deficiencies are recorded before final inspection or occupancy.

Ready to create your Lighting Controls Acceptance?

Free plan available. Set up in 30 seconds, no card required.

No credit cardCancel anytimeSet up in 30 seconds

Create your Lighting Controls Acceptance in minutes