HVAC Technicians Create in CertBox

Economizer Functional Acceptance Test Certificate (Title 24)

An Economizer Functional Acceptance Test Certificate documents the California Title 24 acceptance test for an air economizer’s outdoor/return air dampers and control sequence, performed by a certified Acceptance Test Technician (ATT). It records damper leakage against the 10 CFM/sf limit, high-limit lockout and changeover verification, and — for fixed dry-bulb/enthalpy controls — that the high-limit setpoint is adjustable.

California Title 24, Part 6 (Building Energy Efficiency Standards) §140.4, NRCA-MCH-05-A, AMCA Standard 500-DValid: One-off (no expiry)

No credit card required. Set up in 30 seconds.

Sample Economizer Acceptance Test certificate

Sample Economizer Functional Acceptance Test Certificate (Title 24) certificate created with CertBox, showing the professional PDF layout with economizer/high-limit control type, high-limit setpoint adjustability (fixed dry-bulb/enthalpy controls), damper leakage rate vs. the 10 cfm/sf @ 1.0 in w.g. limit (amca 500-d)

Sample Economizer Acceptance Test with fictional data. All personal details shown are fake.

What it covers

  • Economizer/high-limit control type
  • High-limit setpoint adjustability (fixed dry-bulb/enthalpy controls)
  • Damper leakage rate vs. the 10 CFM/sf @ 1.0 in w.g. limit (AMCA 500-D)
  • Damper open/close operation and actuator condition
  • Changeover, high-limit lockout, sensor calibration, and FDD verification

Who needs a Economizer Acceptance Test?

Mechanical contractors (California)
Certified Acceptance Test Technicians (ATT)
Building departments
Energy code compliance officers

Create your Economizer Acceptance Test with CertBox

1

Fill in the form

Pick Economizer Acceptance Test from the list, fill in the fields on your phone.

2

Compliance checks run

Built-in validation catches missing fields and out-of-range readings.

3

PDF generated instantly

Professional PDF ready to share via secure link or download.

Frequently asked questions about Economizer Acceptance Test

Who can perform a Title 24 economizer acceptance test?
The test must be performed by an Acceptance Test Technician (ATT) certified by a CEC-approved Acceptance Test Technician Certification Provider (e.g. CALCTP), working for an Acceptance Test Employer (ATE), and documented on the CEC compliance form NRCA-MCH-05-A.
What damper leakage rate is required?
Title 24 §140.4 requires outdoor air and return air economizer dampers to have a maximum leakage of 10 CFM per square foot at 1.0 in. w.g., tested per AMCA Standard 500-D (damper leakage Class 1A, 1, or 2).