Elevator & Fire Alarm Technicians Create in CertBox

Elevator Recall & Firefighter's Service Test Certificate

This certificate documents testing of an elevator's firefighter's emergency operation (Phase I recall and Phase II in-car operation) to ASME A17.1, including the annual test of automatic recall from each interfaced fire alarm initiating device required by NFPA 72.

ASME A17.1 (Safety Code for Elevators and Escalators) — Firefighters' Emergency Operations, interfaced with NFPA 72Valid: Monthly Phase I/II key-switch test by the owner's agent; annual fire alarm interface test — some AHJs modify the monthly interval to quarterly, verify locally

No credit card required. Set up in 30 seconds.

Sample Elevator Recall Test certificate

Sample Elevator Recall & Firefighter's Service Test Certificate certificate created with CertBox, showing the professional PDF layout with per-elevator phase i key-switch and automatic recall, designated-level and alternate-level return, phase ii in-car operation

Sample Elevator Recall Test with fictional data. All personal details shown are fake.

What it covers

  • Per-elevator Phase I key-switch and automatic recall
  • Designated-level and alternate-level return
  • Phase II in-car operation
  • Firefighter's hat/switch panel condition
  • Door operation on demand
  • Overall pass/fail result

Who needs a Elevator Recall Test?

Building owners and managing agents
Elevator service companies
Fire alarm contractors
Property/facility managers

Create your Elevator Recall Test with CertBox

1

Fill in the form

Pick Elevator Recall Test from the list, fill in the fields on your phone.

2

Compliance checks run

Built-in validation catches missing fields and out-of-range readings.

3

PDF generated instantly

Professional PDF ready to share via secure link or download.

Frequently asked questions about Elevator Recall Test

How often must firefighter's service be tested?
ASME A17.1 requires the Phase I/Phase II key-switch test monthly, which can be performed by the building owner or a designated agent — no elevator license is required. Automatic Phase I recall from each interfaced fire alarm initiating device must be tested at least annually by qualified elevator personnel. Some jurisdictions modify the monthly interval to quarterly, so check your local AHJ.
Who can perform the monthly test?
The monthly key-switch test can be performed by the building's own trained staff or designated agent. The annual fire-alarm-interface test, which verifies each initiating device actually triggers recall, should be performed by qualified elevator personnel, often coordinated with the fire alarm contractor.

Ready to create your Elevator Recall Test?

Free plan available. Set up in 30 seconds, no card required.

No credit cardCancel anytimeSet up in 30 seconds

Create your Elevator Recall Test in minutes