Ductwork
Supply Air Duct
Rectangular supply air ductwork
CIBSE Guide B
Extract Air Duct
Rectangular extract air ductwork
CIBSE Guide B
Circular Duct
Circular / spiral ductwork section
CIBSE Guide B
Controls
Volume Control Damper
Manual or motorised air volume control damper
CIBSE Guide B
Fire Damper
Fire-rated damper in ductwork penetrating fire compartment wall
BS EN 15650 / CIBSE
Room Thermostat
Room temperature sensor / thermostat
CIBSE Guide H
Thermostatic Radiator Valve
TRV for individual radiator temperature control
CIBSE / BS EN 215
Terminals
Supply Air Terminal
Wall or ceiling supply terminal. Its measured flow rate is recorded at commissioning under TGD Part F rather than taken from the design
CIBSE Guide B
Extract Air Terminal
Wet-room extract terminal. TGD Part F sets minimum extract rates for kitchens, bathrooms and utility rooms, and those rates are measured on site
CIBSE Guide B
Equipment
Air Handling Unit (AHU)
Central air handling unit with filter, coil, and fan sections
CIBSE Guide B
Fan (Axial)
Axial or centrifugal fan
CIBSE Guide B
Heat Recovery Unit (MVHR)
Plate or counter-flow heat exchanger. Common in Irish dwellings built to TGD Part L, where continuous mechanical ventilation with heat recovery is a usual route to compliance
CIBSE Guide B
All 12 at a glance
| Symbol | What it means | Group | Standard |
|---|---|---|---|
| Supply Air Duct | Rectangular supply air ductwork | Ductwork | CIBSE Guide B |
| Extract Air Duct | Rectangular extract air ductwork | Ductwork | CIBSE Guide B |
| Circular Duct | Circular / spiral ductwork section | Ductwork | CIBSE Guide B |
| Volume Control Damper | Manual or motorised air volume control damper | Controls | CIBSE Guide B |
| Fire Damper | Fire-rated damper in ductwork penetrating fire compartment wall | Controls | BS EN 15650 / CIBSE |
| Room Thermostat | Room temperature sensor / thermostat | Controls | CIBSE Guide H |
| Thermostatic Radiator Valve | TRV for individual radiator temperature control | Controls | CIBSE / BS EN 215 |
| Supply Air Terminal | Wall or ceiling supply terminal. Its measured flow rate is recorded at commissioning under TGD Part F rather than taken from the design | Terminals | CIBSE Guide B |
| Extract Air Terminal | Wet-room extract terminal. TGD Part F sets minimum extract rates for kitchens, bathrooms and utility rooms, and those rates are measured on site | Terminals | CIBSE Guide B |
| Air Handling Unit (AHU) | Central air handling unit with filter, coil, and fan sections | Equipment | CIBSE Guide B |
| Fan (Axial) | Axial or centrifugal fan | Equipment | CIBSE Guide B |
| Heat Recovery Unit (MVHR) | Plate or counter-flow heat exchanger. Common in Irish dwellings built to TGD Part L, where continuous mechanical ventilation with heat recovery is a usual route to compliance | Equipment | CIBSE Guide B |