Solar & Renewables · Ireland

Solar & Renewable Symbols - Ireland (I.S. EN 62446 / I.S. 10101)

Irish solar drawings sit under I.S. 10101, the National Rules for Electrical Installations, with I.S. EN 62446-1 governing the testing, documentation and commissioning of the grid-connected system. The paperwork is what marks an Irish installation out: before a microgeneration system is energised, ESB Networks needs an NC6 notification, and the electrical work is certified by a Registered Electrical Contractor through Safe Electric.

This chart has 8 solar & renewables symbols used in Ireland, in 7 groups: Generation, Power Conversion, Storage, Protection, Metering, EV, Heating. Each entry gives the drawing, what it means and the standard it comes from (I.S. EN 62446-1:2016 / I.S. 10101:2020 / ESB Networks NC6).

Last updated

Certs, quotes, invoices. Fill them in on site.

Get started
I.S. EN 62446-1:2016 / I.S. 10101:2020 / ESB Networks NC68 symbols
Share on WhatsApp

Generation

PV Panel / Module

Photovoltaic solar panel

BS 7671 Section 712

PV String

Series-connected group of PV modules

BS 7671 Section 712

Power Conversion

DCAC

Inverter

Converts DC to AC. For microgeneration it must be compliant with the connection conditions ESB Networks accepts on an NC6 notification

BS 7671 / BS EN 62109

Storage

+-

Battery Storage

Battery energy storage system (BESS)

BS 7671 / BS EN 62619

Protection

DC

DC Isolator

Isolates the array from the inverter. Its presence and position are part of what the I.S. EN 62446-1 inspection records

BS 7671 / BS EN 60947-3

Metering

kWhGEN

Generation / Export Meter

Meters generation and export. Export payment in Ireland runs through the smart meter and the supplier rather than a separate generation meter

MCS / BS 7671

EV

EV Charge Point

Electric vehicle charging station

BS 7671 Section 722

Heating

Heat Pump (ASHP)

Air source heat pump outdoor unit

MCS / BS EN 14511

All 8 at a glance

Solar & Renewable Symbols - Ireland (I.S. EN 62446 / I.S. 10101): each symbol, what it means and the standard it comes from
SymbolWhat it meansGroupStandard
PV Panel / ModulePhotovoltaic solar panelGenerationBS 7671 Section 712
PV StringSeries-connected group of PV modulesGenerationBS 7671 Section 712
InverterConverts DC to AC. For microgeneration it must be compliant with the connection conditions ESB Networks accepts on an NC6 notificationPower ConversionBS 7671 / BS EN 62109
Battery StorageBattery energy storage system (BESS)StorageBS 7671 / BS EN 62619
DC IsolatorIsolates the array from the inverter. Its presence and position are part of what the I.S. EN 62446-1 inspection recordsProtectionBS 7671 / BS EN 60947-3
Generation / Export MeterMeters generation and export. Export payment in Ireland runs through the smart meter and the supplier rather than a separate generation meterMeteringMCS / BS 7671
EV Charge PointElectric vehicle charging stationEVBS 7671 Section 722
Heat Pump (ASHP)Air source heat pump outdoor unitHeatingMCS / BS EN 14511

Download this chart

Get a free branded PNG image of all 8 symbols. Print it, pin it to your workshop wall, or save it to your phone.

Share on WhatsApp

Frequently asked questions about solar & renewables symbols

What is an NC6 and when is it needed?
The NC6 is the notification form submitted to ESB Networks for a microgeneration connection. It is sent before the system is connected to the grid, and for domestic installations the registered installer normally submits it. Larger installations use the NC7 route instead.
Which certificate does the electrical work need?
The electrical installation is certified by a Registered Electrical Contractor through Safe Electric, the same route as any other Irish electrical work. That certificate sits alongside the I.S. EN 62446-1 inspection, testing and commissioning report for the PV system itself.
Are Irish solar symbols different from UK ones?
No. Arrays, strings, inverters, isolators, batteries and EV chargers are drawn the same way, because both countries take the symbols from the same international electrical set. The difference is entirely in the standards named and the connection paperwork behind the drawing.
Does the SEAI grant change what has to be drawn?
It changes who may do the work rather than what the drawing shows. Domestic grant-supported installations must be carried out by an installer registered with SEAI and working to its code of practice for domestic solar PV, and the documentation that code expects is the same commissioning evidence I.S. EN 62446-1 describes.

Create solar & renewables certificates on your phone

153 certificate types, filled in on your phone and signed on site. Quotes and invoices too.

Get started free
Symbols based on I.S. EN 62446-1:2016 / I.S. 10101:2020 / ESB Networks NC6. This is a reference guide only. Always consult the full standard for official symbol definitions.