Airtightness Testers Create in CertBox

Air Pressure Test Certificate

An Air Pressure Test Certificate (also called an Air Tightness Test) records the measured air permeability of a building envelope. In England, Approved Document L asks for a test on every new dwelling. It is carried out by a tester registered with ATTMA or the Elmhurst Airtightness Scheme (EAS, formerly iATS), using a fan (blower door) at 50 Pa or a low-pressure pulse test at 4 Pa. For Building Regulations the tester lodges the test with their scheme, which issues the lodgement certificate that goes with the report.

Building Regulations Part L (England), Approved Document L, CIBSE TM23, ATTMA TSL1/TSL2Valid: One-off (at completion)

Free to fill in. £4.99 to send one, or £14.99 a month for as many as you like.

Sample Air Tightness Test certificate

Sample Air Pressure Test Certificate certificate created with CertBox, showing the professional PDF layout with building measurements (floor area, envelope area, volume), test method and equipment details, air permeability result at 50 pa, or at 4 pa for a pulse test

Sample Air Tightness Test with fictional data. All personal details shown are fake.

What it covers

  • Building measurements (floor area, envelope area, volume)
  • Test method and equipment details
  • Air permeability result at 50 Pa, or at 4 Pa for a pulse test
  • Pass/fail against Part L target
  • Wind conditions and temperature correction

Who needs a Air Tightness Test?

New build developers
Self-builders
Building Control

Create your Air Tightness Test with CertBox

1

Fill in the form

Pick Air Tightness Test from the list, fill in the fields on your phone.

2

Send the PDF

Download it, email it to your customer or share a link. Sending is the part you pay for.

Frequently asked questions about Air Tightness Test

Is an air tightness test mandatory?
For new dwellings in England, yes. Approved Document L (2021) paragraph 7.4 says an air pressure test should be carried out on every dwelling. Extensions do not need one.
What is the pass threshold?
Under Approved Document L (2021 edition, in force since June 2022), the limiting (worst-case) air permeability for new dwellings is 8 m³/(h·m²) at 50 Pa. With a pulse test the limit is 1.57 m³/(h·m²) at 4 Pa. Most designs target 3-5 m³/(h·m²) at 50 Pa. The energy calculation is then rerun with the measured figure, and must still meet its targets (paragraph 7.5).